Growatt Inverter Error Codes: What 04, 07, 302, 409 and the Others Mean (Philippines 2026)

A plain-English list of Growatt inverter error codes, taken from Growatt's own manuals for the SPF off-grid inverters (SPF 3500/5000 ES, SPF 6000 ES Plus) and the MIN and SPH grid-tie and hybrid inverters. Which codes you can deal with yourself (a flat battery after a brownout, overload, Error 302 when the grid is down), and which ones are for an electrician or Growatt.

Most Growatt error codes mean the inverter is protecting itself, not that it's broken. First, check how many digits the code has. Two-digit codes (01, 04, 07, 56…) come from Growatt's SPF off-grid inverters, the ones many Leyte and Biliran homes use for brownout backup. Three-digit codes ("Error 302", "Error 409") come from the MIN grid-tie and SPH hybrid inverters. The ones people search for most:

  • SPF 04: battery voltage too low. Usually just a flat battery after a long brownout. Cut the load and let it recharge.
  • SPF 07: overload timed out. Too many appliances at once. Switch some off.
  • SPF 56: battery connection open, from a loose cable or blown fuse. Electrician.
  • SPF 08, 09, 53, 57: internal faults. Restart once, then the repair centre.
  • MIN/SPH Error 302: "No AC connection". Normal during a brownout, since grid-tie solar has to stop.
  • MIN Error 409: bus over-voltage. Restart once, then call Growatt.

Last checked 12 November 2026, against Growatt's SPF 3500/5000 ES manual (v4.0), SPF 6000 ES Plus manual (EN 202212), MIN 2.5–6K TL-XH2 manual and SPH 3000–6000TL BL-UP manual (EN 202512). Code lists differ between model families, so match the code to the manual for your exact model.

First, safety

An SPF inverter brings solar DC, battery DC and grid or generator AC together in one box. Growatt's SPF safety instructions say:

  • Don't open it. "Do not disassemble the unit. Take it to a qualified service center when service or repair is required."
  • Switching it off isn't enough. "Disconnect all wirings before attempting any maintenance or cleaning. Turning off the unit will not reduce this risk."
  • Watch metal tools near batteries. A dropped tool can "spark or short circuit batteries… and could cause an explosion."

So below, "you" means no tools and no cables. You can read the screen, switch loads off, clear space around the unit, let the battery recharge and do one restart. Anything on the battery or DC side (cables, fuses, battery settings, panel strings) or the AC wiring is a job for a licensed electrician or your installer.

Which Growatt do you have? Read the code first

What you see

Inverter family

Examples sold in PH

Where the list comes from

Two-digit number with the fault icon, red LED solid, buzzer continuous

SPF off-grid (fault)

SPF 6000 ES Plus

SPF manual "Fault Reference Code"

Two-digit number flashing, red LED flashing, beeps once a second

SPF off-grid (warning, unit keeps running)

SPF 6000 ES Plus

SPF manual "Warning Indicator"

"Error 3xx / 4xx" on the small screen

MIN grid-tie

MIN TL-X / TL-XH

MIN manual, section 11

"Error 5xx / 6xx" plus battery messages

SPH hybrid

SPH 5000TL BL-UP

SPH manual, section 9.2

Sungrid Energy's Growatt page currently lists the SPF 6000 ES Plus off-grid inverter and the SPH 5000TL BL-UP hybrid, among others. Take a photo of the screen before you press anything. The code, the time and what was running are what an installer will ask for. If you're still deciding on a brand, our LuxPower vs Growatt vs Deye comparison covers warranty and backup output.

Growatt SPF fault codes (01–81)

The SPF 3500/5000 ES and SPF 6000 ES Plus manuals list the same 21 fault codes. On a fault, output stops: the fault icon shows, the red LED stays on and the buzzer beeps continuously. "What Growatt says" comes from the manual's troubleshooting table. The "Who acts" column is our advice.

Code

Growatt's meaning

What Growatt says

Who acts

01

Fan is locked

Check all fans are working; replace the fan

Installer

02

Over temperature

Internal temperature over 100 °C. Check airflow isn't blocked and the room isn't too hot; check the thermistor plug

You first (airflow), then installer

03

Battery voltage too high

Battery over-charged. Check the battery spec and number of batteries

Installer

04

Battery voltage too low

Measure battery voltage; check SOC on a lithium battery; recharge the battery

You first (let it recharge), then electrician

05

Output short circuited

Check wiring and remove the abnormal load

Electrician

06 / 58

Output voltage too high / too low

Output above 280 Vac or below 80 Vac. Reduce the load, restart once

You (load), then repair centre

07

Overload time out

Overloaded above 110% for too long. Switch off some equipment

You

08

Bus voltage too high

With a lithium battery without BMS communication, check programs 19 and 21 aren't set too high; restart once

Installer

09 / 53 / 57

Bus soft start failed / inverter soft start failed / current sensor failed

"Internal components failed": restart once, then return to repair centre

Repair centre

51

Over current or surge

Restart once, then repair centre

You (restart), then repair centre

52

Bus voltage too low

Restart once, then repair centre

Repair centre if it repeats

55

Over DC voltage in AC output

Listed as "output voltage is unbalanced" in troubleshooting

Installer

56

Battery connection is open

Battery not connected well or fuse burnt. If wiring is fine, restart; if it repeats, repair centre

Electrician (DC side)

60

Negative power fault

Parallel systems: check AC output isn't wired to grid input, program 8, current-sharing cables, neutrals

Installer

61

PV voltage is too high

No fix listed. Panel string over the inverter's limit

Installer, urgently

62

Internal communication error

No fix listed

Repair centre

80 / 81

CAN fault / host loss

Parallel systems: check parallel cables and program 23

Installer

Two quick notes. Fault 61 is about panel wiring: the SPF 5000 ES accepts at most 450 V open-circuit from the panels and the SPF 6000 ES Plus 500 V, so an over-voltage string needs rewiring, not a restart. Our multimeter guide explains how Voc is measured. Faults 08 and 56 often come back to battery setup, so read the next section too.

Growatt SPF warning codes (the unit keeps running)

Warnings flash on the screen, the red LED flashes and the buzzer usually beeps once a second. The inverter keeps working, but something needs attention.

Code

Growatt's meaning

What it usually means at home

01

Fan locked while inverter is on

Fan blocked or failing; installer

02

Over temperature

Hot room, blocked vents

03

Battery over-charged

Charge settings; installer

04

Low battery

Battery getting flat; cut loads now, before fault 04

07

Overload

Too much load; beeps every 0.5 s

10

Output power derating

Inverter limiting itself, often from heat

12

Solar charger stops due to low battery

Battery too flat for the solar charger

13

Solar charger stops due to high PV voltage

Panel voltage too high; installer

14

Solar charger stops due to overload

Charger at its limit

15–17, 22, 25

Parallel system warnings

Only on two or more inverters in parallel; installer

18

Buck over current

Installer if it repeats

19

Battery disconnect

Battery not seen (no beep); check the battery breaker is on, then electrician

20

BMS communication error

Lithium battery not talking to the inverter: cable or protocol setting

21

PV power insufficient

Cloudy, shaded or dirty panels, or early/late in the day

33

BMS communication loss

Same as 20

34–45

Battery BMS warnings (cell over/under voltage, over/under temperature, MOSFET over temperature, system shut down)

The battery itself is protecting; check the battery's own manual

For warning 20, Growatt's troubleshooting table gives two checks: the communication cable between inverter and battery, and whether the BMS protocol type is set correctly. On an SPF, Program 05 must be set to "LI" before Program 36 (protocol) appears. If a lithium battery has no communication cable, the manual says to use "User-Defined 2" in Program 05 instead. These are installer settings. Our battery not charging guide covers the battery side.

Why fault 04 hits after a long brownout

Fault 04 is the code people search for most, and in Biliran and Leyte it usually turns up at night after a long brownout. For lead-acid batteries, Growatt sets the SPF 5000 ES warning and cut-off voltages by load. The heavier the load, the lower the voltage it lets the battery fall to before stopping:

Load on the inverter

Low DC warning (warning 04)

Warning clears at

Low DC cut-off (fault 04)

Under 20%

44.0 V

46.0 V

42.0 V

20% to under 50%

42.8 V

44.8 V

40.8 V

50% or more

40.4 V

42.4 V

38.4 V

Bar chart of Growatt SPF 5000 ES lead-acid battery thresholds by load. Under 20% load: warning 04 at 44.0 V, clears at 46.0 V, fault 04 cut-off at 42.0 V. 20% to under 50% load: warning 42.8 V, clears 44.8 V, cut-off 40.8 V. 50% or more: warning 40.4 V, clears 42.4 V, cut-off 38.4 V. Cold start needs 46.0 V.
Source: Growatt SPF 3500/5000 ES user manual v4.0, Table 2; checked 12 November 2026.

In lithium mode the SPF 5000 ES works by state of charge instead: cut-off at 20% SOC by default (settable 5–50%), warning at cut-off + 5%, and it needs 30% SOC (cut-off + 10%) to cold-start from the battery. In lead-acid mode the cold-start voltage is 46.0 V. That's why an inverter that shut down on fault 04 often won't come back on battery alone. It needs sun or grid to recharge first. If yours won't power on at all, our inverter not turning on guide goes through the checks.

Worked example A: a fault 04 night in Naval (Solar Leyte illustration)

A home in Naval has an SPF 5000 ES with a 48 V AGM battery bank. During a 7 pm brownout it runs a ref, fans, lights and the TV, about 1,500 W. That's 1,500 ÷ 5,000 = 30% load, so the "20% to under 50%" row applies.

  1. When the battery falls to 42.8 V, warning 04 flashes and the unit beeps once a second. This is your cue to switch off everything except the ref.
  2. If nothing changes, at 40.8 V the inverter shows fault 04 and cuts the output.
  3. When the grid comes back, the SPF charges the battery from the grid again. If the brownout is still on, it waits for the sun. On battery alone it won't restart until the bank is back above 46.0 V.

If fault 04 keeps coming back on short brownouts even after a full sunny day, the battery may have lost capacity. Have an electrician test it.

Fault 07 and the aircon problem

The SPF 5000 ES is rated 5,000 W. Growatt's overload protection allows 10 seconds at 110–150% load and 5 seconds at 150% or more, with a surge capacity of twice the rated power for 5 seconds. After that it shows fault 07.

Worked example B: aircon plus water pump (Solar Leyte illustration)

Load

Share of 5,000 W

What the SPF does (per Growatt's spec)

4,800 W

96%

Runs normally

6,000 W

120%

Warning 07, then fault 07 after 10 seconds

8,000 W

160%

Fault 07 after 5 seconds

5,000 × 110% = 5,500 W and 5,000 × 150% = 7,500 W are our calculations. The fix is simple: don't start the aircon, the water pump and the flat iron at the same time on battery. Program 06 sets whether the unit restarts by itself after an overload (default: disabled). Our solar for aircon guide explains what an aircon really draws.

"Mains exist but the unit works in battery mode"

This one confuses a lot of SPF owners in towns where evening voltage sags. Program 03 sets which AC input voltages the SPF will accept:

  • Appliance (default): 90–280 Vac
  • UPS: 170–280 Vac
  • Generator: 90–280 Vac (Growatt says the generator should be at least 10 kVA)

If Program 03 is set to UPS and your evening voltage dips below 170 V, the SPF stays on battery even though the lights in the house next door are on. Growatt's troubleshooting table says to check whether the AC wires are too thin or too long, whether the generator is working well, and "if input voltage range setting is correct (UPS→Appliance)". It lists one more cause with the same flashing green LED: Program 01 (output priority) set to solar or battery first. Growatt's fix there is to change the output priority to "Utility first" if you want the grid to carry the load. Our AVR guide explains what low voltage does to other appliances.

Growatt MIN and SPH error codes (three digits)

Grid-tie (MIN) and hybrid (SPH) inverters use three-digit codes. Growatt splits them into system faults, which are usually caused by something outside the inverter, and inverter faults.

Code

Model family

Growatt's meaning

What Growatt says

Who acts

Error 201

MIN

Residual current (leakage) too high

Restart; if it persists, contact Growatt

Installer

Error 202

MIN, SPH

PV voltage high

Disconnect the DC switch immediately, check each string's voltage

Installer, urgently

Error 203

MIN, SPH

PV insulation resistance low

Check panel frame and inverter grounding, wet DC breaker, PV-to-ground impedance

Electrician

Error 300

MIN, SPH

AC voltage out of range

Check grid voltage and AC wiring, especially neutral and ground

You (wait), then electrician

Error 302

MIN, SPH

No AC connection

Check AC wiring and the AC breaker

You: check for a brownout first

Error 303

MIN

PE abnormal (neutral-to-earth over 30 V)

Check N and PE voltage and AC wiring

Electrician

Error 304

MIN, SPH

AC frequency out of range

Restart; check AC wiring

You (wait), then installer

Error 402

MIN, SPH

Output high DCI

Restart; contact Growatt if it persists

Installer

Error 404 / 405

MIN

Bus sample fault / relay fault

Restart; contact Growatt if it persists

Installer

Error 407

MIN

Auto test failure

Restart and repeat the auto test

Installer

Error 408

MIN

Over-temperature

Wait until the inverter's surroundings are below 60 °C, then restart

You (shade, airflow)

Error 409

MIN

Bus over-voltage

Restart; contact Growatt if it persists

Installer

Error 411 / 414 / 417

MIN

DSP–M3 communication, EEPROM, data mismatch

Restart; firmware update or board replacement

Installer / Growatt

Error 420

MIN

GFCI fault

Restart; contact Growatt if it persists

Electrician

Error 500

SPH

BMS COM fault

Check the battery communication port

Installer

Error 502 / 503

SPH

Battery voltage low / high

Check battery voltage

You (recharge), then installer

Error 505 / 506

SPH

Battery reversed / battery open

Check battery terminals

Electrician (DC side)

Error 600 / 604 / 607

SPH

Output short / EPS volt low / EPS overload

Restart; for EPS volt low, check and reduce the load on the backup (EPS) port

You (load), then electrician

The MIN manual also lists warnings that leave the inverter running: Warning 203 (PV1 or PV2 short circuit: check panel polarity), 205 (PV boost failure), 401 (inverter can't talk to the export meter: check the meter is on and connected), 404 (EEPROM) and 405 (inconsistent firmware). Some numbers, like 203 and 404, appear as both an "Error" and a "Warning" with different meanings, so read the word in front of the number.

Worked example C: Error 302 during a BILECO brownout (Solar Leyte illustration)

At 2 pm the power goes out in Naval. The MIN grid-tie inverter on the roof stops and its screen says Error 302, No AC connection, even though it's sunny. That's expected. A grid-tie inverter without a battery must stop when the grid goes down. This "anti-islanding" protects linemen working on the lines (Meralco's net-metering FAQ, question 19). When the line comes back, the inverter reconnects by itself. Only call someone if Error 302 stays on while the grid is up and your AC breaker for the inverter is on.

Error 300 is the cousin. The MIN TL-XH2 accepts grid voltage of 160–276 V, so a deep evening sag or a surge can trip it even with the power on. If it happens daily, ask BILECO or your LEYECO to check your supply voltage. Our brownout vs blackout guide explains the voltage limits.

When to call someone, and what to send them

Growatt's MIN manual lists what support will ask for: serial number, model, the error message, a short description, grid voltage, DC input voltage, whether you can reproduce it, whether it happened before, the conditions at the time, and your panel details (model, watts, Voc, Vmp, Imp, panels per string). Have those ready and you'll save a site visit.

  • You can handle: SPF 04 and warning 04 (recharge, cut loads), 07 (overload), 02 and Error 408 (heat and airflow), warning 21 (low sun), Error 302 during a real brownout.
  • Electrician or installer: 03, 05, 08, 56, 61, warnings 19, 20 and 33, Errors 201, 202, 203, 303, 420, 500–506.
  • Repair centre or Growatt: 09, 53, 57, 62, and anything that comes back after one restart.

Growatt's own contact page lists offices in places like Thailand, Vietnam and Australia but none in the Philippines, plus a global service email (service@growatt.com). In practice, warranty claims go through the shop or installer that sold you the unit, so keep the receipt and serial number. If the inverter is out of warranty and you're thinking of replacing it, you can request a quote and compare.

Diagram grouping Growatt inverter error codes into three columns. You can usually sort it: SPF 04 and warning 04 low battery, cut loads and recharge; SPF 07 overload, switch loads off; SPF 02 and Error 408 too hot, clear the airflow; warning 21 PV power low on a cloudy day; Error 302 no AC connection, check for a brownout; Error 300 and 304 grid out of range, wait. Restart once: SPF 51 and 52; Errors 402, 404 and 405; Error 409 bus over-voltage; if it comes back, repair centre or Growatt. Call a professional: SPF 03 and 56 battery high or open; SPF 61 and Error 202 PV voltage too high; warnings 19, 20 and 33 battery or BMS link; Errors 203 and 303 insulation or earthing; Errors 505 and 506 battery reversed or open; SPF 08, 09, 53 and 57 internal faults.
Who should act on each Growatt code. Sources: Growatt SPF, MIN and SPH user manuals; grouping by Solar Leyte, checked 12 November 2026.

FAQ

What does error 04 mean on a Growatt inverter?

On an SPF off-grid inverter, it means the battery voltage is too low. As a warning (flashing), it's telling you to cut loads now. As a fault, output has stopped. Growatt says to measure the battery voltage, check the SOC on lithium, and recharge.

How do I reset a Growatt SPF fault?

Growatt's note says that to restart, disconnect all power sources and wait until the LCD goes off, then boot from the battery only. Do it once. If the same fault comes back, especially 08, 09, 53, 56 or 57, stop and call an electrician or the repair centre.

Ano ang Error 302 sa Growatt?

"No AC connection." Ibig sabihin, walang kuryente galing sa grid, kaya normal ito kapag may brownout. Babalik ang inverter kapag bumalik na ang kuryente. Kung may kuryente pero Error 302 pa rin, ipa-check ang AC breaker at wiring sa electrician.

Is Growatt error 409 serious?

On a MIN inverter, 409 is "bus over-voltage", an inverter fault. Growatt says restart it, and if the problem continues, contact Growatt. It isn't something to fix at home.

Solar Leyte is run by MACC Systems & Energy Solutions Inc., a solar installer in Naval, Biliran.

Get a free solar quote from MACC

Planning a hybrid or off-grid system for brownouts? Send us a recent BILECO or LEYECO bill and we'll get back to you with a free, no-obligation written quote.

Related guides

Sources (all checked 12 November 2026)

Free quote · Leyte & Biliran

Thinking about solar? Get a free quote from MACC.

Send us your monthly kWh use (it's on your BILECO or LEYECO bill) and what you want solar to do: lower your bill, keep the lights on in a brownout, or both. MACC Systems & Energy Solutions Inc. will reply with an itemised quotation.